반응 #54905
ord-0c1c367d3ea64a0d92066fd5febe77bf
반응 방정식
반응 조건
후처리
- 1세척eluted with carbonate/bicarbonate buffer as above, with a flow rate of 1.8ml/h
- 2workup.WAITUnreacted gentamicin left the column first
- 3기타well separated from the gentamicin peak
- 4세척was not eluted
실험 절차
Gentamicin (1mM) and fluorescein isothiocyanate (FITC) (1.25mM) were allowed to react in 0.05M sodium carbonate/bicarbonate buffer, pH 9.0, for 2 hours at room temperature. 2ml of the reaction mixture was applied to a column (1 × 97cm) of G-15 grade Sephadex and eluted with carbonate/bicarbonate buffer as above, with a flow rate of 1.8ml/h. Column fractions (1.8ml) were assayed for gentamicin content by radio-immunoassay and for fluorescein content by fluorimetry. FIG. 1 of the accompanying drawings shows the result. Unreacted gentamicin left the column first. The FTC-G product exited next, well separated from the gentamicin peak. Unreacted FITC was very strongly held on the G-15 column and was not eluted.