Reacción #1885018
ord-17486d738a2c4222accc3f0fe7e47b71
Ecuación de reacción
Reactantes
Reactivos
Disolventes
Condiciones de reacción
Tratamiento posterior
- 1OtroInto a 100 mL three-neck flask were put
- 2OtroAfter the mixture was degassed under low pressure
- 3workup.ADDITIONAfter the stirring, toluene was added into the mixture
- 4Lavadothe organic layer was washed with a saturated aqueous solution of sodium carbonate and brine in this order
- 5workup.ADDITIONAfter the washing, magnesium sulfate was added into the organic layer
- 6Otroto dry the organic layer
- 7FiltraciónAfter the drying, the mixture was subjected to suction filtration
- 8Otroto give a filtrate
- 9FiltraciónThe obtained filtrate was subjected to suction filtration through Celite (manufactured by Wako Pure Chemical Industries, Ltd., Catalog No. 531-16855)
- 10Otroto give a filtrate
- 11ConcentraciónThe obtained filtrate was concentrated
- 12Otropurification by silica gel column chromatography
- 13ConcentraciónAn obtained fraction was concentrated
- 14Otroto give a solid
- 15OtroThe obtained solid was recrystallized with a mixed solvent of chloroform and hexane
Procedimiento
Into a 100 mL three-neck flask were put 7.0 g (22 mmol) of 2-(4-iodophenyl)benzoxazole, 4.4 g (22 mmol) of 2-bromophenylboronic acid, 0.049 g (0.22 mmol) of palladium(II) acetate, and 0.46 g (1.5 mmol) of tri(o-tolyl)phosphine. Into the mixture were added 60 mL of 1,2-dimethoxyethane (DME) and 30 mL of a 2M aqueous solution of potassium carbonate. After the mixture was degassed under low pressure, the atmosphere in the flask was substituted by nitrogen. This mixture was stirred at 90° C. for 10 hours. After the stirring, toluene was added into the mixture and the organic layer was washed with a saturated aqueous solution of sodium carbonate and brine in this order. After the washing, magnesium sulfate was added into the organic layer to dry the organic layer. After the drying, the mixture was subjected to suction filtration to give a filtrate. The obtained filtrate was subjected to suction filtration through Celite (manufactured by Wako Pure Chemical Industries, Ltd., Catalog No. 531-16855) to give a filtrate. The obtained filtrate was concentrated, and purification by silica gel column chromatography was performed. The column chromatography was performed first using a mixed solvent of chloroform and hexane (chloroform:hexane=1:4) as a developing solvent and then using a mixed solvent of chlorofoini and hexane (chloroform:hexane=1:1) as a developing solvent. An obtained fraction was concentrated to give a solid. The obtained solid was recrystallized with a mixed solvent of chloroform and hexane to give 2.2 g of a powdery white solid in a yield of 29%.