Reaction #2329020

ord-6a20d7b72fb446bea6d27702264e2e59

Reaction equation

O=S(=O)([O-])[O-].O=c1ccc2ccc(O)cc2o1
7-HC sulphate
O=c1ccc2ccc(O)cc2o1
7-HC
O=c1ccc2ccc(O)cc2o1
7-hydroxycoumarin
CCOc1ccc2ccc(=O)oc2c1
7-ethoxycoumarin

Conditions

Detailed conditions
See reaction.notes.procedure_details.

Workup

  1. 1
    Otherto yield a 10 μg/ml solution
  2. 2
    Otherto yield a 10 μg/ml solution

Procedure

Four standards were used: 7-ethoxycoumarin, which was prepared as 1 mg/ml solution in methanol, and 10 μg/ml solutions prepared from the 1 mg/ml solutions in distilled water; the Phase I metabolite of ECOD, 7-hydroxycoumarin (7-HC), which was prepared as a 1 mg/ml solution in 50:50 methanol:water, and 10 μg/ml solutions diluted in distilled water; the Phase II metabolite, 7-HC-glucuronide, which was prepared as a 1 mg/ml solution in 50:50 methanol:water, and subsequently diluted in distilled water to yield a 10 μg/ml solution; and 7-HC-sulphate, prepared as a 1 mg/ml solution in 50:50 methanol:water, and subsequently diluted in distilled water to yield a 10 μg/ml solution. ECOD elutes between 12.919 to 14.647 minutes from the column, while 7-HC elutes at 3.709 to 4.668 minutes. The subsequent breakdown product, 7HC-glucuronide, is retained at 2.265 to 3.947 minutes, and 7HC-sulphate is retained from 10.230 to 12.878 minutes.

Source

DOI: 10.6084/m9.figshare.5104873.v1Patent: US07670797B2uspto-grants-2010_03