Lösungsmittel

Reaktionsbedingungen

Temperatur
40°CELSIUS
Detaillierte Bedingungen
See reaction.notes.procedure_details.

Aufarbeitung

  1. 1
    Sonstigewhile measuring with syringe

Vorschrift

In an autoclave, 3.22 mg of RuBr2[(S,S)-xylskewphos](3,5-Me2pica) (3.39×10−3 mmol, S/C=1000) and 7.62 mg of potassium tert-butoxide (6.79×10−2 mmol) are placed, replaced with argon gas. Under argon gas flow, 0.5 mL of 2′,6′-dichloro-3′-fluoroacetophenone (3.39 mmol, from Jiangxi Jixiang Pharmachemical) and 2.9 mL of 2-propanol are added while measuring with syringe, pressurized with hydrogen to 10 atm., stirred at 40° C. for 21 hours, and the reduction of hydrogen pressure was confirmed and (S)-1-(2,6-dichloro-3-fluorophenyl)ethanol was obtained at 100% yield. The optical purity measured by HPLC (DAICEL CHRALPAK AD-RH, acetonitrile/water=25/75, 0.5 mL/min, 25° C., 220 nm, the retention time of each enantiomer: (S): 56.1 min, (R): 64.5 min) was 98.5% ee.

Quelle

DOI: 10.6084/m9.figshare.5104873.v1Patent: US09174906B2uspto-grants-2015_11