Reaktion #68734
ord-c8e3dfd703da496dbe1b8ec4c2014a7d
Reaktionsgleichung
calcium carbonate
6-deoxy L-mannose
6-deoxy L-mannose
hydrogen
→
6-deoxy L-mannitol
Reagenzien
Keine
Lösungsmittel
Reaktionsbedingungen
Detaillierte Bedingungen
See reaction.notes.procedure_details.
Aufarbeitung
- 1Sonstigereaction volume of 600 g
- 2SonstigeReaction
- 3Sonstigewas retained at 50° C.
Vorschrift
24 g of Raney-nickel obtained by the method described above was added to 300 g of an aqueous solution containing 100 g of 6-deoxy L-mannose in a 1-L glass autoclave with an agitator and a thermometer, to which water was added to a final reaction volume of 600 g. So as to adjust the reaction mixture to pH 7, then, calcium carbonate was added. Reaction was progressed while the temperature was retained at 50° C.; the hydrogen pressure was retained at 12 kg/cm2 (gauge pressure); the agitation speed was retained at 700 rpm. The reaction mixture was analyzed by HPLC. Consequently, 6-deoxy L-mannose was decreased to 1% in the 8-hour reaction, to produce 6-deoxy L-mannitol.